Model No.︰HM3319E
Brand Name︰HarmonyWOLRD/OEM/ODM
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
It is mainly used for the determination of impact toughness of non-metallic materials such as hard plastics, reinforced nylon, glass fiber reinforced plastics, ceramics, cast stone, electrical insulating materials, etc. It is an ideal testing equipment for chemical industry, scientific research institutions, colleges and universities, quality inspection and other departments. The main technical parameters of HM3319E series cantilever beam impact testing machine fully comply with the requirements of IS0180, GB/T 1843, GB/T 2611, and JB/T 8761 standards.
Features
This machine adopts Chinese and English contrast, touch screen display operation, PLC module control, can store 5 sample data and calculate the average value of impact strength, and realize dual printing of test reports in Chinese and English, simple operation and stable performance. This machine is currently one of the best alternatives to imported instruments in China. The energy of this machine can be choosed when ordering. The impact energy of the cantilever beam is any one of 1J, 2.75J, 5.5J, 11J, 22J.
Performance
This machine has functions of angle measurement and zeroing; energy loss measurement and automatic compensation; automatic calculation of impact strength, standard deviation, etc., and can print test reports in Chinese and English, with high measurement accuracy and fast test speed, etc.
SPECIFICATION
HM3319E5.5 series |
HM3319E22 series |
|
Impact velocity |
3.5 m/s |
|
Pendulum energy |
1J、2.75J、5.5J |
11J、22J |
Strike center distance |
322mm |
|
Pendulum angle |
160° |
|
Blade radius |
R=0.8±0.2mm |
|
Distance from blade to jaw |
22±0.2mm |
|
Impact angle |
75° |
|
Pendulum empty impact energy loss |
1J:2%;2.75J、5.5J:1% |
0.50% |
PW-3319E-5.5 series |
PW-3319E-22 series |
|
Impact velocity |
3.5 m/s |
|
Pendulum energy |
1J、2.75J、5.5J |
11J、22J |
Strike center distance |
322mm |
|
Pendulum angle |
160° |
|
Blade radius |
R=0.8±0.2mm |
|
Distance from blade to jaw |
22±0.2mm |
|
Impact angle |
75° |
|
Pendulum empty impact energy loss |
1J:2%;2.75J、5.5J:1% |
0.50% |